When it comes to the data center environment, the most common problems encountered are air conditioning and power failure. Air conditioning failure can lead to high temperatures, high or low humidity, and water flooding. Power failure can lead to costly network, server, and Web site downtime, not to mention the cost to replace or fix expensive servers and systems. Extreme temperature changes due to failed heating or cooling equipment, malfunctioning components, or even seasonal changes can damage hardware, threaten uptime, block network access, destroy data, and be expensive to recover from. AVTECH Softwares Room Alert 26W safeguards your valuable equipment by alerting staff when environment changes occur. Room Alert 26W monitors rooms ranging from small unmanned phone or wiring closets to large corporate data centers. And the Room Alert WiSH (Wireless Sensor Hub) sensors are battery-powered and communicate directly with the main unit, so the Room Alert 26W can monitor virtually anywhere, indoors and out, up to 250 feet away. | AVTECH Room Alert 26W $1,195 An advanced hardware solution for monitoring computer room temperature, humidity, power, flooding, and much more in multiple locations (888) 220-6700 www.RoomAlert.com  | With the Room Alert 26W, situations that could lead to expensive recovery can be addressed quickly and before they cause damage, downtime or lost revenue.
Easy To Use Room Alert 26W is an easy to use solution that does not require a host PC to operate. Simply plug Room Alert 26W into your network via Ethernet and then place WiSH sensors and other external sensors in the desired locations. You can set up the Room Alert 26W via the built-in Web server interface in minutes. The 26Ws Web server interface lets you visually check current sensor status, change configuration settings, set up alert thresholds, and calibrate sensors if needed. Firmware updates are easily completed with the click of a button, ensuring your Room Alert 26W ID Box is running with all the latest features and enhancements. And the cost of the Room Alert 26W can be justified quickly—often the first time it warns of a threatening condition and enables staff to resolve an issue before it becomes a major problem.
Easy Choice Environment conditions in todays dense IT data centers are a major concern facing managers. Power outages, air conditioning failures, or blocked ventilation can cause temperatures to rise to 85 or 95 degrees or higher in minutes. Room temperatures over 85 degrees will damage equipment and put data at risk. That makes the Room Alert 26W an easy choice, monitoring in real time and providing the peace of mind you want. With the Room Alert 26W, you get: An easy, economical, and reliable way to monitor, log, and document while protecting your data center from environmental dangers. Alert notifications via email, email-to-SMS, SNMP, and more to many types of devices. A built-in Web server interface that displays the real-time temperature and humidity, wireless sensor status, environment sensor status, current alarm status, and much more. PageR Enterprise software to log temperature, humidity, and sensor status from the Room Alert 26W ID Box for record keeping; it allows easy export to create reports and graph trends. A built-in digital temperature, digital humidity, power, flood sensor (just add cable), and UPS. Secure wireless sensor monitoring that eliminates the need for cables and offers unlimited monitoring options. Youll be able to: Know immediately when and where important or critical environment changes or extremes occur. Allow staff to be more responsive, taking action to save data and equipment before environment changes can cause problems or disasters. Create a more lights out IT environment, without the need for onsite staff to monitor temperature, humidity, and other environment changes in person, reducing staff costs.
Whats Included With The Room Alert 26W Standard options with the $1,195 package: Room Alert 26W 1U 19-inch rack model Built-in digital temperature sensor Built-in digital humidity sensor Built-in main power sensor Built-in flood sensor (just add cable) One external digital temperature sensor One external room entry sensor Six external digital sensor ports 16 sets of switch sensor contacts for connection of additional external environment sensors Built-in UPS One WiSH (Wireless Sensor Hub) PageR 20 Object Enterprise software license Power adapter, 10-foot Ethernet cable, printed and PDF documentation, CD media, and Getting Started materials Additional options include: External digital sensors for temperature/humidity, temperature, and power External switch sensors for temperature, humidity, power, flood, smoke, motion, sound, light, air flow, room entry, and more PageR Enterprise software license upgrades International plug adapter |
|